All calculations

Thermal Expansion & Expansion Joint Movement

How far the line grows, the movement asked of the expansion joint, and the stroke needed with cold pull.

Unit system

Inputs

Total growth

79.81mm

Stroke asked of the joint

39.91mm

Details

Growth per metre1.995 mm
Operating temperature used179.9 °C
Rise above installation159.9 K
Mean expansion coefficient (1/K)1.248e-5
NoteWith cold pull the same bellows serves nearly twice the run; it is compressed 39.9 mm the other way on installation.

Assumptions

  • The MEAN expansion coefficient is used (referenced to 20 °C), not the instantaneous one. That is the correct one for total growth.
  • The line is assumed free to grow. Intermediate guides and friction reduce the real movement somewhat but raise the anchor loads.

Continue with this result

Calculation report

A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.

Source

  • EN 13480-3 · Termal genleşme
  • EJMA · Ön germe (cold pull) uygulaması

Results are for engineering pre-assessment and are not a product selection commitment. Final responsibility rests with the user.

Terms of use