Continuous Flow Heating — Condensate Load

The steam demand and trap capacity for heating a liquid flowing continuously through an exchanger.

Unit system

Inputs

Steam demand = condensate load

2,417kg/h

Heat duty

1,432kW

Details

Trap capacity (with safety factor)3,625 kg/h
Steam temperature143.6 °C
Latent heat2,133 kJ/kg
Steam-to-outlet approach63.61 K
AssessmentThe temperature difference is workable; size the trap on the full-load capacity.

Assumptions

  • Only the LATENT heat of the steam is used. Condensate leaves at saturation; sub-cooling reduces the steam demand slightly.
  • Specific heat is taken as constant; over a wide range enter a mean value.

Continue with this result

Calculation report

A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.

Source

  • Enerji dengesi · Q = ṁ·cp·ΔT ÷ verim; ṁ_buhar = Q ÷ h_fg
  • IAPWS-IF97 (R7-97) · Doyma sıcaklığı ve gizli ısı · 2007