Improved Dryness by Pressure Reduction

Dryness after throttling; give a separator efficiency and the dryness after separation follows.

Unit system

Inputs

Outlet dryness

0.9310

State at outlet

Wet steam — no separator

Details

Dryness after throttling (before separator)0.9310
Conserved enthalpy2,576 kJ/kg
Outlet temperature133.5 °C
Superheat at outlet0 K
Remaining moisture fraction0.0690

Assumptions

  • Throttling is isenthalpic: enthalpy is conserved, with no work or heat exchange. No energy is ADDED; the same energy corresponds to a higher dryness.
  • Separator efficiency is the fraction of INCOMING moisture removed; the separated water leaves as condensate and the steam flow drops accordingly.

Calculation report

A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.

Source

  • Termodinamik · İzentalpik kısılma — h₁ = h₂
  • IAPWS-IF97 (R7-97) · Doyma entalpileri · 2007

Results are for engineering pre-assessment and are not a product selection commitment. Final responsibility rests with the user.