Condensate Recovery Economics

The annual value of recovering condensate across energy, water, chemicals and blowdown.

Unit system

Inputs

Total annual saving

110,574

Energy component

74,574

Details

Water component30,000
Chemicals component6,000
Condensate reaching the boiler2,000 kg/h
Lost as flash steam0 kg/h
Returned condensate temperature143.6 °C
Heat recovered300.9 kW
Annual CO₂ avoided396.4 t/yıl
System noteClosed system: the condensate returns hot with no flash loss.

Assumptions

  • THE BLOWDOWN SAVING IS NOT INCLUDED HERE. Returning condensate dilutes the feedwater TDS and cuts the blowdown needed; that term shows up in the Blowdown Rate calculation and adds on top of this total.
  • The condensate is taken as saturated water at the trap outlet. Sub-cooled condensate flashes less and an open system loses less.
  • Capital cost (piping, pump, tank) is not included; this gives the annual SAVING, not the payback period.

Calculation report

A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.

Source

  • Enerji ve kütle dengesi · Dönen kondensin ham suya göre fazlası
  • IAPWS-IF97 (R7-97) · Kondens ve ham su entalpileri · 2007
  • Yakıt kütüphanesi · CO₂ katsayıları

Results are for engineering pre-assessment and are not a product selection commitment. Final responsibility rests with the user.