Expansion Joint Reaction & Anchor Load
The total load an anchor sees from pressure thrust and spring force, and what a tied joint changes.
Inputs
Total anchor load (N)
65,942
Total load (kN)
65.94
Details
| Pressure thrust (N) | 52,942 |
| Spring force (N) | 8,000 |
| Friction (N) | 5,000 |
| Effective area used | 0.05891 m² |
| Load in tonnes-force | 6.72 |
| Dominant term | Pressure thrust dominates — the anchor is set by pressure, not by the bellows. A softer bellows does NOT reduce this load. |
Assumptions
- The thrust is computed on GAUGE pressure; atmosphere acts on the outside and pushes back.
- Effective area and spring rate are MANUFACTURER data. The estimate here gives the order of magnitude; the anchor’s structural design must use catalogue figures.
Calculation report
A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.
Source
- EJMA · Kompansatör reaksiyon kuvvetleri
- EN 14917 · Basınçlı metal körüklü kompansatörler
Results are for engineering pre-assessment and are not a product selection commitment. Final responsibility rests with the user.