Air Mixed in Steam — Temperature Drop
Given the air fraction, the real steam temperature and the degrees lost against pure steam.
Inputs
Actual steam temperature
130°C
Temperature lost
3.557K
Details
| Verdict | Noticeable — heat-up takes longer |
| If it were pure steam | 133.5 °C |
| Partial pressure of steam | 2.7 bar a |
Assumptions
- Dalton’s law of partial pressures: the steam partial pressure is the total pressure times the steam volume fraction.
- This gives only the TEMPERATURE loss. Air also forms an insulating film on the surface and lowers the heat-transfer coefficient — the real effect is larger than shown here.
Calculation report
A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.
Source
- Dalton kısmi basınç yasası · p_buhar = p_toplam × (1 − hava oranı)
- IAPWS-IF97 (R7-97) · Bölge 4 — kısmi basınçtan doyma sıcaklığı · 2007