Safety Relief Valve Sizing
Required orifice area and bore from the relieving capacity, set pressure and overpressure.
Inputs
Required orifice area
0.002013m²
Equivalent bore
50.62mm
Details
| Flow regime | Critical (choked) flow — back pressure does not affect capacity |
| Relieving pressure (absolute) | 12.01 bar a |
| Density at relief | 6.132 kg/m³ |
| Back-pressure ratio | 0.0843 |
| Critical ratio | 0.5774 |
Assumptions
- Kdr is the manufacturer’s certified value. The figure here is for pre-sizing; the final selection follows the valve’s own certificate.
- The result is the REQUIRED area. Pick the next standard orifice up from the catalogue (API letter or manufacturer code).
Calculation report
A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.
Source
- ISO 4126-1 · Emniyet vanaları — boyutlandırma
- ISO 4126-1 · Kritik ve alt-kritik akış katsayıları
- IAPWS-IF97 (R7-97) · Boşaltma şartlarındaki yoğunluk · 2007
Results are for engineering pre-assessment and are not a product selection commitment. Final responsibility rests with the user.