All calculations

Deaerator Steam Consumption

The steam spent bringing feedwater to deaerator temperature, and its share of the boiler load.

Unit system

Inputs

Deaerator steam use

911.7kg/h

Share of feedwater

0.0887

Details

Deaerator temperature111.4 °C
Vented30.82 kg/h
Heating duty615.9 kW
Makeup plus condensate inflow9,393 kg/h

Assumptions

  • Mixing is taken as adiabatic; the vessel’s surface loss is not included (small on an insulated deaerator).
  • This steam never reaches the process. Boiler capacity must cover production PLUS the deaerator’s own use.

Calculation report

A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.

Source

  • Enerji dengesi · W·h_buhar + (F−W)·h_giriş = F·h_çıkış + vent
  • IAPWS-IF97 (R7-97) · Entalpiler · 2007

Results are for engineering pre-assessment and are not a product selection commitment. Final responsibility rests with the user.

Terms of use