Condensate from Compressed Air

The water dropping out after the compressor and aftercooler, the dew point, and the cooler’s latent load.

Unit system

Inputs

Condensate formed

7.28kg/h

Water per day (litres)

174.7

Details

Pressure dew point at outlet35 °C
Dew point at intake19.15 °C
Intake humidity ratio (kg/kg dry air)0.01392
Outlet humidity ratio0.00441
Latent load on the aftercooler5.057 kW
Water per year (m³)44

Assumptions

  • The air is taken as SATURATED at the aftercooler outlet. With a dryer the dew point falls further and condensation continues there.
  • Air is an ideal gas; the water vapour partial pressure comes from the IAPWS-IF97 saturation curve.

Calculation report

A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.

Source

  • Psikrometri · W = 0,621945 · p_buhar ÷ (p − p_buhar)
  • IAPWS-IF97 (R7-97) · Su buharı doyma basıncı · 2007

Results are for engineering pre-assessment and are not a product selection commitment. Final responsibility rests with the user.