Pressure Reducing Station

The Kv of the reducing valve, and the capacity the downstream safety valve must pass if the reducer fails open.

Unit system

Inputs

Kv required for the reducer

10.92

Fail-open flow — the safety valve must pass this

2,931kg/h

Details

Cv required for the reducer12.62
Fail-open flow ÷ duty flow1.47
Safety valve required area0.001264
Safety valve equivalent bore40.11 mm
Flow regime in the reducerChoked flow at duty

Assumptions

  • The fail-open flow uses the valve’s FULLY OPEN rated Kv. Using the duty Kv would undersize the safety valve — the valve is throttled at duty, not in failure.
  • A rising downstream pressure REDUCES flow; what enlarges the fail-open flow is the fully open port, not the back pressure.
  • The safety valve area assumes 10 % overpressure and discharge to atmosphere.

Calculation report

A PDF carrying the inputs, results, assumptions and the source. A one-time code is sent to your address.

Source

  • IEC 60534-2-1 · Düşürücü vana kapasitesi
  • ISO 4126-1 · Alçak basınç tarafı korumasının boyutlandırılması

Results are for engineering pre-assessment and are not a product selection commitment. Final responsibility rests with the user.